DATA PROGRAMMING
Assignment of FCH Related Data
•Connection Link (for Data)
C_RT: 11
TCL=4 LSG=13
STEP 3: ACTK
Assign the Connection Trunk data for
Example: (When using 512kbps (8ch) TS as Connection link)
•Connection trunk
C_RT: 10 | TK: | CLENS: LEN for the SDT |
•Connection Link
| C_RT: 11 | TK: | CLENS: LEN for the FCH |
| C_RT: 11 | TK: | CLENS: LEN for the SDT |
Note: Set the switch on the FCH card depending on the transmission speed. | |||
See “CHAPTER 4 INSTALLATION” for more information on switch settings. | |||
STEP 4: | AFCH |
|
|
| Assign the FCCH number for each FCCH. | ||
| FCHN: 2 (FCCH number) | FCHEN: LEN of FCCH | |
STEP 5: | AFPC |
|
|
| Assign the FCCS routing data. |
| |
| FPC: 1 (FPC of the adjacent node) FCCH: 1 (with FCCH) | ||
| CRT: 10 |
| FCHN: 2 |
STEP 6: | ACAN |
|
|
| Assign the CIC number to the connection trunk. | ||
| FPC: 1 | FCIC: | CLENS: LEN of the connection trunk |
STEP 7: | AFRT |
|
|
| Assign the FCCH Controlled Connection Route data. | ||
| FCHN: 2 | CRT: 10 |
|
ND-70185 (E)CHAPTER 5
Page 95
Revision 3.0