9.4 FLTINF = 1EH Spanning Tree Generation End

TROUBLESHOOTING

23-U FCH Status Information

9.4 FLTINF = 1EH Spanning Tree Generation End

This message is displayed when Spanning Tree Generation is complete. The detailed information is indicated in the following format.

"Spanning Tree Generation End"

 

 

 

 

 

 

 

 

 

 

 

 

1. xx 0x 1E xx

xx xx xx xx

2. xx xx

xx xx xx xx

xx xx

3. xx xx

xx xx xx xx

xx xx￿

4. xx xx xx xx

xx xx xx xx

5. xx xx

xx 00 0000

0000

6. 00 00 00 00 00 00

00 00

 

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

b0

 

 

 

 

 

 

 

 

7

6

5

4

3

2

1

-

 

 

 

 

 

 

 

 

15

14

13

12

11

10

9

8

 

 

 

 

 

 

 

 

23

22

21

20

19

18

17

16

 

 

 

 

 

 

 

 

..............

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

........

 

 

 

 

 

 

 

 

239

238

237

236

235

234

233

232

 

 

 

 

 

 

 

 

247

246

245

244

243

242

241

240

 

b7

 

 

 

 

b0

 

255

254

253

252

251

250

249

248

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Each bit represents FPC (Fusion Point Code). When "1" is set, the FPC has joined the spanning tree configuration.

 

:

 

 

 

 

:

 

 

32 Bytes

 

:

 

 

 

 

 

 

 

:

 

 

 

b7

 

 

 

 

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

Spanning Tree Configuration Results

 

b7

b0

 

 

1E

b7

 

b0

0

0

 

TRC RS

FCH CKT No.

 

 

b0

FLTINF: 1EH = Spanning Tree Generation End Notification

TRC: Trace Confirmation Bit￿

(0/1 = Status Notification / Primitive Trace)￿

RS: Receive / Send Primitive Trace (not effective)￿ FCH CKT No. = Circuit No. of FCH

Manual background MG

 

 

 

 

 

 

 

 

 

MG: Module Group ￿

U

 

 

G

 

 

 

 

 

 

 

 

 

 

U: Unit (0-3)￿

 

 

 

 

 

 

 

FCH Mounting Location

 

 

 

G: Group (0-23)

Figure 7-21 23-U FCCH Status Notification - Spanning Tree Generation End

ND-70185 (E)CHAPTER 7

Page 165

Revision 3.0

Page 180
Image 180
NEC NEAX2400 system manual Troubleshooting, FLTINF = 1EH Spanning Tree Generation End, ND-70185ECHAPTER Page Revision