NEC NEAX2400 System Considerations, System Configuration, 6 Non-RedundantConfiguration, Chapter

Models: NEAX2400

1 213
Download 213 pages 13.1 Kb
Page 29
Image 29
Figure 3-6 Non-Redundant Configuration

SYSTEM CONFIGURATION

System Considerations

In Figure 3-6, no redundancy is shown in the Fusion link.

In this case, no redundancy is taken as to Fusion link.

CPU#0

CPU#1

PCI Bus

PCI Bus

LANI#0

 

 

 

 

 

 

 

 

10 Base T

 

 

....

10 Base T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HUB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LANI#1

 

 

 

 

 

 

 

 

10 Base T

 

 

 

 

 

FCH

DTI

Figure 3-6 Non-Redundant Configuration

3.System Considerations

3.1Fusion Network Conditions

This section explains how to design a Fusion network. In the following diagram, a Fusion Link is printed in a thick line while a CCIS link is printed in a dotted line.

Condition 1: The maximum number of nodes on a Fusion network is sixteen (16) nodes.

example 1

 

Node A

FCCS

 

 

 

3

 

 

FCCS

FCCS

4

FCCS

Node B

1

FCCS

example 2

Node A

FCCS

1

FCCS

Node C

 

Node B

FCCS

 

2

Node C

2

Node D

Node D

 

FCCS

 

 

 

 

 

 

Routing from Node A

Node C

Routing from Node D

Node C

1

Node A

Node B

Node D Node C ￿

1

Node D

Node A

Node B Node C ￿

2 Node A

Node D

Node C

2

Node D

Node B

Node C

3

Node A

Node B

Node C ￿

 

 

 

 

4Node A 3.System ConsiderationsNode C

example 3

 

example 4

 

Node B

 

 

FCCS

 

FCCS

FCCS

Node A FCCS Node B FCCS Node C FCCS Node D

Node A

Node C

Node D

 

FCCS

 

Node E

Figure 3-7 Fusion Network Topologies

CHAPTER 3

ND-70185 (E)

Page 14

Revision 3.0

Page 29
Image 29