DATA PROGRAMMING

Assignment of System Data

Index 800

 

 

For ASYDL

b0 : 0/1 = ALGNL, ALGSL on a UGN (TN) basis/-

 

b1

: 0/1 = ASPAL on a TN basis/-

 

b2

: 0/1 = ANPDL on a TN basis/-

 

b4

: 0/1 = AFRSL, ASTPL, AUNEL on a TN basis/-

 

b5

: 0/1 = ASTPL on a TN basis/-

 

b7

: 0/1 = AAEDL on a TN basis/-

For ASYDN

b0 : 0/1 = ALGNN, ALGSN on a UGN (TN) basis/-

 

b1

: 0/1 = ASPAN on a TN basis/-

 

b2

: 0/1 = ANPDN on a TN basis/-

 

b4

: 0/1 = AFRSN, ASTPN on a TN basis/-

 

b5

: 0/1 = ASTPN on a TN basis/-

 

b6

: 0/1 = ARSCN on a TN basis/-

 

b7

: 0/1 = AAEDN on a TN basis/-

When “different numbering development on a TN basis ” is not required, set the above bits.

This figure shows the display of the ASYDN command Index 514 as an example.

1

Figure 5-7 ASYDN Command Display (example)

Note 4: Be sure to execute “Non-Load Initial” after setting the FPC data. The assigned FPC becomes effective by this operation.