NEC NEAX2400 system manual Acan

Models: NEAX2400

1 213
Download 213 pages 13.1 Kb
Page 118
Image 118
STEP 7: ACAN

DATA PROGRAMMING

Assignment of FCH Related Data

STEP 7: ACAN

Assign the Fusion Connection Index Code (FCIC) for the Next Node.

FPC (Fusion Point Code): Assign FPC number of the Next Node (Node to be passed to).

FCIC (Fusion Connection Index Code): Assign Fusion CIC of the Next Node (Node to be passed to).

C_LENS (Connection_LENS): Assign DTI LENS data (Bch data), specified in STEP 2.

PBX

RT10

speech

FCIC1: 002010

FCIC2: 002011

FCIC3: 002012

FCIC10: 002022

DTI

FCH

Fusion Network

Speech

RT11

Signal

ACAN command parameters

RT15

RT14

HUB

FPC

 

FPC￿

ROUTER

11

(Next Node)

 

 

 

FGH

 

FCIC

FCHN is not required ￿

1

 

 

for FGH

 

DTI

 

C_LENS

External LAN

002010

 

 

 

DTI

FCHN=1

Note

 

 

MDF

Note: This setting is a sample.

 

 

FCH

FCHEN: 000030

 

HUB

Internal LAN

 

 

 

CPU

LANI

Figure 5-48 Sample Data Assignment (ACAN)

STEP 8: MBCT

Unbusy the connection trunk data assigned in the previous steps, by using the MBCT command, This is required for FCH, FGH trunks as well as speech channels.