DATA PROGRAMMING
Assignment of FCH Related Data
STEP 7: ACAN
Assign the Fusion Connection Index Code (FCIC) for the Next Node.
FPC (Fusion Point Code): Assign FPC number of the Next Node (Node to be passed to).
FCIC (Fusion Connection Index Code): Assign Fusion CIC of the Next Node (Node to be passed to).
C_LENS (Connection_LENS): Assign DTI LENS data (Bch data), specified in STEP 2.
PBX
RT10
speech
FCIC1: 002010
FCIC2: 002011
FCIC3: 002012
FCIC10: 002022
DTI |
FCH
Fusion Network
Speech
RT11
Signal
ACAN command parameters
RT15
RT14
HUB | FPC |
| FPC |
ROUTER | 11 | (Next Node) | |
|
|
|
FGH |
| FCIC | |
FCHN is not required | 1 | ||
| |||
| for FGH |
| |
DTI |
| C_LENS | |
External LAN | 002010 | ||
| |||
|
| ||
DTI | FCHN=1 | Note | |
| |||
| MDF | Note: This setting is a sample. | |
|
| ||
FCH | FCHEN: 000030 |
| |
HUB | Internal LAN |
| |
|
|
CPU
LANI
Figure 5-48 Sample Data Assignment (ACAN)
STEP 8: MBCT
Unbusy the connection trunk data assigned in the previous steps, by using the MBCT command, This is required for FCH, FGH trunks as well as speech channels.
ND-70185 (E)CHAPTER 5
Page 103
Revision 3.0