DATA PROGRAMMING
Assignment of FCH Related Data
STEP 7: ACAN
Assign the Fusion Connection Index Code (FCIC) for the Next Node.
FPC (Fusion Point Code): Assign FPC number of the Next Node (Node to be passed to).
FCIC (Fusion Connection Index Code): Assign Fusion CIC of the Next Node (Node to be passed to).
C_LENS (Connection_LENS): Assign DTI LENS data (Bch data), specified in STEP 2.
PBX
RT10
speech
FCIC1: 002010
FCIC2: 002011
FCIC3: 002012
FCIC10: 002022
DTI |
FCH
Fusion Network
Speech
RT11
Signal
ACAN command parameters
RT15
RT14
HUB | FPC |
| FPC |
ROUTER | 11 | (Next Node) | |
|
|
|
FGH |
| FCIC | |
FCHN is not required | 1 | ||
| |||
| for FGH |
| |
DTI |
| C_LENS | |
External LAN | 002010 | ||
| |||
|
| ||
DTI | FCHN=1 | Note | |
| |||
| MDF | Note: This setting is a sample. | |
|
| ||
FCH | FCHEN: 000030 |
| |
HUB | Internal LAN |
| |
|
|
CPU
LANI
Figure
STEP 8: MBCT
Unbusy the connection trunk data assigned in the previous steps, by using the MBCT command, This is required for FCH, FGH trunks as well as speech channels.
Page 103
Revision 3.0