POST INSTALLATION TEST

FCCS Network Connection Test

3.2ATTCON Connection Test (via FCCS)

Perform the ATTCON connection test, using the following procedure.

Check

3.2.1 ATTCON Call Origination Test

STEP 1: Dial the operator access code (normally “0”), from STN A in Node A.

STEP 2: Confirm that the ATT lamp flashes and ringer sounds at each ATTCON in Node B.

STEP 3: Answer the call by pressing the ATND key.

STEP 4: Confirm the speech condition is sufficient (no noise, not one-party speech, etc.).

STEP 5: Release the call by pressing the CANCEL key.

STEP 6: Replace the handset of STN A in Node A.

Check

3.2.2 ATTCON Call Termination Test

STEP 1: Press a LOOP key on an ATTCON in Node B.

STEP 2: Dial the Telephone Number of STN A.

STEP 3: Confirm the ringer sounds properly at STN A.

STEP 4: Answer the call and confirm￿ the speech condition is sufficient (no noise, not one-way speech, etc.).

STEP 5: The operator at the ATTCON releases the call by pressing the CANCEL key.

STEP 6: Replace the handset of STN A in Node A.

Operator Access ￿

Node A (Self-Node)

Code "0"

 

STN A

LC

TELN: 410000

STN: 2000

FCCS

Node B

RI

NG

 

IN

 

 

G

ATI

ATTCON

TELN: Telephone Number STN: Physical Station Number

Figure 6-9 ATTCON Connection Test (origination) via FCCS