Alarm Configuration Options

ACCULINK 317x E1 DSU/CSU

Alarm Configuration Options

Table C-8

Alarm Configuration Options

Alrm Msg: Disab

Next Enab Disab Prev

Alarm Messages. Controls the generation of alarm messages, which are routed to an ASCII terminal or printer attached to the communication port. For more information, refer to the Alarms section in Chapter 4, Maintenance.

Enab ± Enables alarm messages routed to the communication port.

Disab ± Prevents alarm messages for any alarm conditions.

NOTE: Alarm messages are only sent to the communication port if the Com Use configuration option is set to ASCII, otherwise the alarm messages are discarded.

SNMP Trap: Disab

Next Enab Disab Prev

SNMP Trap Enable. Specifies whether SNMP trap messages are sent over the SNMP management link. For more information, refer to the SNMP Traps section in Chapter 4, Maintenance.

Enab ± Enables sending SNMP trap messages from this unit over any SNMP management link.

Disab ± Disables sending SNMP trap messages from this unit over any SNMP management link.