Paradyne 317x E1 manual Selecting the DTE Drop/Insert or Data Port for LED Display

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 33
Image 33
Selecting the DTE Drop/Insert or Data Port for LED Display

Operation

Selecting the DTE Drop/Insert or Data Port for LED Display

Use the LED command on the Control branch to select which port's (DTE Drop/Insert or data port) status appears on the five shared LEDs on the front panel.

To select a port for LED display,

1.From the top-level menu screen, press Changing Configuration Options once to scroll the Ctrl name onto the screen.

DSU E1 CEPT

Stat

Test

Cnfig

F1

F2

F3

2. Press F3 to select Ctrl.

DSU E1 CEPT

Test Cnfig Ctrl

F1 F2 F3

3. From the Control screen, select LED.

Control:

 

Rel

LED

ClrReg

F1

F2

F3

The currently selected port name appears on the top line of the LCD. DTE indicates the DTE Drop/Insert port.

LED Dsply: DTE

DTE

Prt1

Prt2

F1

F2

F3

4.From the LED Dsply screen, press the Function key that corresponds to the DTE Drop/Insert or data port for which you want the LEDs to display. Use the scroll keys, if necessary.

Select DTE to monitor the DTE Drop/Insert port's SIG, OOF, ALRM, PDV, and BPV status signals on the shared LEDs.

Select a particular data port to monitor the data port's DTR, TXD, RXD, CTS, and RTS control signals on the shared LEDs.

Changing Configuration Options

The E1 DSU/CSU is an intelligent device that displays only valid options for the current configuration. Therefore, you are only presented with menu choices that are consistent with the current configuration and operational state of the E1 DSU/CSU; invalid combinations of configuration options do not appear. For example, menus displayed for the Model 3172 (2 ports) and the Model 3174 (4 ports) differ due to the number of ports available. Also, if the DTE Drop/Insert interface selection is disabled, many of the menu choices do not appear. Be aware that although all options are shown in this guide, what you see on your E1 DSU/CSU varies with your configuration.

The E1 DSU/CSU offers four sets of configuration options located in the following memory areas:

Active (Activ). The configuration option set active for the E1 DSU/CSU is stored here. Before a configuration option set becomes active for the E1 DSU/CSU, you must save the set to the Active area. When the E1 DSU/CSU is shipped from the factory, the Active configuration option set is identical to the Factory set. This area can be written to and controls the current operation of the device.

Customer 1 (Cust1). The first of two sets of customer-defined configuration options. This area can be written to.

Customer 2 (Cust2). The second of two sets of customer-defined configuration options. This area can be written to.

Factory (Fact). This is a set of configuration options preset at the company. This set is determined by what is considered to be the most common configuration used in the E1 DSU/CSU market. Factory options are read-only.

3170-A2-GB20-20

December 1996

3-11

Page 33
Image 33
Paradyne 317x E1 manual Selecting the DTE Drop/Insert or Data Port for LED Display, Changing Configuration Options