Paradyne 317x E1 manual Test Commands, Remote Loopback Tests

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 73
Image 73
Test Commands

ACCULINK 317x E1 DSU/CSU

Test Commands

The test commands enable you to run loopbacks and test patterns on the E1 DSU/CSU, and to test the front panel LEDs. These tests can help you isolate areas of trouble if you are having problems with your E1 DSU/CSU.

To access all Test commands from the Test branch, press F2 to select Test from the top-level menu screen.

DSU E1 CEPT

Stat Test Cnfig

F1 F2 F3

Remote Loopback Tests

The Remote Loopback tests enable you to troubleshoot your circuit by sending the following to a far-end E1 DSU/CSU:

Data channel loopback up (DCLBUP) activation sequence to initiate a V.54 Loop 2

Data channel loopback down (DCLBDN) deactivation sequence to terminate a V.54 Loop 2

You cannot perform remote loopbacks if any of the local loopbacks are active. If you attempt to do so, the error message Invld Test Combo (Invalid Test Combination) appears.

To send a Data Channel Activation or Deactivation loopback sequence to the far-end E1 DSU/CSU,

1.Press F2 to select Test from the top-level menu screen.

2.From the Test screen, press F1 to select Rlpbk.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3.From the Rem Loopback screen, press the Function key that corresponds to the specific loopback test you want to perform.

Rem Loopback:

DCLBUP DCLBDN

F1 F2 F3

The Rem Loop screen appears, where Type is either DCLBUP or DCLBDN.

Rem Loop: Type

Prt1 Prt2 Prt3

F1 F2 F3

The DCLBUP and DCLBDN commands send the requested sequence out the network interface on the DS0 channels allocated to the port you select here.

4.From the Rem Loop screen, press the desired Function key to select the specific port. Use the scroll keys, if necessary.

After you select a port, the sequence is sent to the far-end E1 DSU/CSU. During this time, Sending appears on Line 2 of the LCD, followed by Command Complete when the sequence is complete.

During the Sending message, you can press the Remote Loopback Tests and Manual background keys without affecting transmission of the loopback sequence.

4-14

December 1996

3170-A2-GB20-20

Page 73
Image 73
Paradyne 317x E1 manual Test Commands, Remote Loopback Tests