Paradyne 317x E1 manual of Troubleshooting, Symptom, Possible Cause, Solutions, AIS at DTE

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 71
Image 71
(2 of 2)

ACCULINK 317x E1 DSU/CSU

Table 4-6

(2 of 2)

Troubleshooting

Symptom

Possible Cause

Solutions

Message

DTE is sending an AIS.

Check the DTE.

AIS at DTE

 

 

 

 

appears

 

 

 

 

 

 

 

Message EER at

E1 facility problem.

Contact your E1 facility provider.

Net appears

 

 

 

 

 

 

 

 

 

BPV LED is ON

1.

Incompatible line coding format between the

1.

Check that the line coding format for the DTE

 

 

DTE and the E1 DSU/CSU.

 

Drop/Insert interface is correct.

 

2.

DTE Drop/Insert cable problem.

2.

Check that the DTE cable is securely attached

 

 

 

 

at both ends.

 

 

 

A failure message

Internal E1 DSU/CSU problem.

Record the 8-digit code, then contact your

appears followed

 

 

field service representative.

by an 8-digit code

 

 

 

 

(# # # # # # # # )

 

 

 

 

 

 

 

 

 

SNMP link is

1.

The SNMP manager configuration is

1.

Check that the configurations are matched.

down

 

mismatched with the device configuration.

2.

Start the link layer protocol.

 

2.

The SNMP manager's link layer protocol is not

 

 

 

 

 

running.

 

 

 

 

 

 

 

No SNMP

1.

Cable problem.

1.

Check that the cable is securely attached at

communication

2.

The link layer protocol is not running.

 

both ends.

via the AUX port

2.

Change the Aux Use configuration option to

 

 

 

 

 

 

 

 

 

None, and then back to SNMP or Daisy (as

 

 

 

 

appropriate).

 

 

 

 

 

4-12

December 1996

3170-A2-GB20-20

Page 71
Image 71
Paradyne 317x E1 manual of Troubleshooting, Symptom, Possible Cause, Solutions, AIS at DTE, # # # # # # # #