ACCULINK 317x E1 DSU/CSU

Output Signal Table ± ªrs232OutSigChangesº (rs232OutSigEntry 4)

This object is not supported by the E1 DSU/CSU.

Generic-Interface Extension MIB (RFC 1229)

The generic-interface MIB is an experimental MIB that provides extensions to the generic interface group defined in MIB II. This MIB describes three tables:

Generic Interface Extension Table

Generic Interface Test Table

Generic Receive Address Table

Only the generic interface test table is supported by the

E1 DSU/CSU. This table is supported for the network interface only.

Generic Interface Test Table, Generic Interface MIB

The test table provides access to additional tests (loopbacks and pattern tests) that are not in the interface group of MIB II.

Generic Interface Test Table ± ªifExtnsTestTypeº Object (ifExtnsTestEntry 4)

This object is a control variable used to start and stop operator-initiated tests on the interface. It provides the capability to:

Start/stop the Send 1-in-8 test pattern on the network interface.

Start/stop the Send QRSS/511 test pattern on a synchronous data port.

Start sending a V.54 UP/DOWN code to the remote unit for a synchronous data port.

Start/stop the Monitor QRSS/511 test pattern on a synchronous data port.

Start/stop the DCLB/DTLB loopback test on a synchronous data port.

The following object identifiers control tests on the interface.

noTest ± Stops the test in progress on the interface.

testFullDuplexLoopBack ± Initiates a DCLB on the interface. Only supported for the data ports.

testLoopDTLB ± Initiates a DTLB on the interface. Only supported for the data ports.

testMonQRSS ± Initiates a Monitor QRSS test on the interface. Only supported for the data ports.

testMon511 ± Initiates a Monitor 511 test on the interface. Only supported for the data ports.

testSendQRSS ± Initiates a Send QRSS test on the interface. Only supported for the data ports.

testSend511 ± Initiates a Send 511 test on the interface. Only supported for the data ports.

testSendV54Up ± Sends a V54 Up code to the remote unit. Only supported for the data ports.

testSendV54Down ± Sends a V54 Down code to the remote unit. Only supported for the data ports.

testSend1in8 ± Initiates a Send 1-in-8 test on the network interface.

Where these object identifiers are defined as follows:

noTest ± OBJECT IDENTIFIER ::= [wellKnownTests 0]

testFullDuplexLoopBack ± OBJECT IDENTIFIER ::= [wellKnownTests 1]

testLoopDTLB ± OBJECT IDENTIFIER ::= [wellKnownTests 2]

testMonQRSS ± OBJECT IDENTIFIER ::= [wellKnownTests 3]

testMon511 ± OBJECT IDENTIFIER ::= [wellKnownTests 4]

testSendQRSS ± OBJECT IDENTIFIER ::= [wellKnownTests 5]

testSend511 ± OBJECT IDENTIFIER ::= [wellKnownTests 6]

E-14

December 1996

3170-A2-GB20-20

Page 144
Image 144
Paradyne 317x E1 manual Generic-Interface Extension MIB RFC, Output Signal Table ± ªrs232OutSigChangesº rs232OutSigEntry