Paradyne 317x E1 manual Correlation between Menu Commands and SNMP Objects, Front Panel Command

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 146
Image 146
Correlation between Menu Commands and SNMP Objects

ACCULINK 317x E1 DSU/CSU

Correlation between Menu Commands and SNMP Objects

Table E-1 provides a correlation between how a function is performed or status is displayed on the front

panel and how the same function is accomplished using access to the SNMP database. SNMP objects are displayed in bold type while values for SNMP objects are displayed in italics.

Table E-1

(1 of 3)

SNMP MIB to Front Panel Command Cross-Reference

Front Panel Command

SNMP MIB Object

 

 

Stat±>DevHS:

Read the dsx1LineStatus object for NET E1

LOS at NET

dsx1LossOfSignal

OOF at NET

dsx1LossOfFrame

RAI at NET

dsx1RcvFarEnd

AIS at NET

dsx1RcvAIS

EER at NET

dsx1OtherFailure

 

 

Stat±>DevHS:

Read the dsx1LineStatus object for DTE E1

LOS at DTE

dsx1LossOfSignal

OOF at DTE

dsx1LossOfFrame

RAI at DTE

dsx1RcvFarEnd

AIS at DTE

dsx1RcvAIS

 

 

Stat±>Perf±>NET±>Cur:

Read the value in following objects for NET E1

CurTimer

dsx1TimeElapsed

ES

dsx1CurrentES

UAS

dsx1CurrentUAS

SES

dsx1CurrentSES

BES

dsx1CurrentBES

 

 

Stat±>Perf±>NET±>Intvl±>Dsply:

Select the interval number with dsx1IntervalNumber. Read the value

 

in the following objects for the NET E1

ES

dsx1IntervalES

UAS

dsx1IntervalUAS

SES

dsx1IntervalSES

BES

dsx1IntervalBES

VldIntvl

dsx1ValidIntervals

 

 

Stat±>Perf±>NET±>24Tot:

Read the value in the following objects for NET E1

VldIntvl

dsx1ValidIntervals

ES

dsx1TotalES

UAS

dsx1TotalUAS

SES

dsx1TotalSES

BES

dsx1TotalBES

 

 

E-16

December 1996

3170-A2-GB20-20

Page 146
Image 146
Paradyne 317x E1 manual Correlation between Menu Commands and SNMP Objects, Front Panel Command, SNMP MIB Object