Paradyne 317x E1 Table C-2 4 of Port Configuration Options, Far-end Disab Next Disab Maint Prev

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 93
Image 93
Table C-2

ACCULINK 317x E1 DSU/CSU

Table C-2

(4 of 4)

Port Configuration Options

Far-end: Disab

Next Disab Maint Prev

Far-End Performance Statistics. Specifies whether to monitor for far-end performance report messages (PRMs) and maintain far-end performance registers for a particular port.

Disab ± Disables far-end performance statistics.

Maint ± Monitors the port's EDL for PRMs and maintains far-end performance statistics.

NOTE: This configuration option is not available and does not appear if EDL is disabled.

NOTE: If the local E1 DSU/CSU is configured to maintain far-end performance statistics, then the remote E1 DSU/CSU must be configured to send near-end performance statistics.

Mgmt Link: Disab

Next Disab SNMP Prev

EDL Management Link. Specifies whether the EDL management link is enabled for a particular port. Selecting SNMP allows SNMP management traffic to flow over the 4 kbps in-band data link provided by EDL.

Disab ± Disables the port's EDL management link.

SNMP ± Enables the port's EDL management link.

NOTE: This configuration option is not available and does not appear if EDL is disabled or FDL is enabled for SNMP.

NOTE: If the local E1 DSU/CSU's EDL is enabled, then the remote E1 DSU/CSU's EDL must also be enabled.

C-6

December 1996

3170-A2-GB20-20

Page 93
Image 93
Paradyne 317x E1 manual Table C-2 4 of Port Configuration Options, Far-end Disab Next Disab Maint Prev