ACCULINK 317x E1 DSU/CSU

7.When you press F3 from the NET Registers screen, the interval screen appears. Use this screen to choose the specific 15-minute interval.

NET Intvl: 01

Up Down Dsply

F1 F2 F3

8.Use the and keys to position the cursor under the first or second digit in the interval number displayed, then use the F1 (Up) and

F2 (Down) keys to increment/decrement the number.

9.When you have selected the number of the interval you want to display, press F3 (Dsply) to display the registers for the interval selected.

NET Intvl: nn

ES=xxx

F1 F2 F3

10.Use the scroll keys to view additional register information.

You can reset the network registers from the E1 DSU/CSU via the ClrReg command in the Control branch of the front panel menu.

To clear the user performance registers,

1.Press the key on the top-level menu screen to bring the Ctrl branch onto the front panel LCD.

DSU E1 CEPT

Stat Test Cnfig

F1 F2 F3

2.Press F3 to select Ctrl from the top-level display screen.

DSU E1 CEPT

Test Cnfig Ctrl

F1 F2 F3

3. Select ClrReg.

Control:

 

Rel

LED

ClrReg

F1

F2

F3

4.From the Clear Prf Regs screen, press F1 to clear the NET registers.

Clear Prf Regs:

NET Prt1 Prt2

F1 F2 F3

If you selected NET, the network performance registers are cleared. All accumulators are reset to zero and all status registers are cleared, and the current interval timer, the number of valid intervals count and the total 24-hour counts are reset to zero. The Command Complete screen then appears.

Clear NETRegs:

Command Complete

F1 F2 F3

4-6

December 1996

3170-A2-GB20-20