Com Use:

Operation

7.Press F2 to configure the COM port as the management link to an external SNMP manager.

Com Use:

Next SNMP ASCII

F1 F2 F3

Setting the IP Address

The IP address is the address used by the SNMP manager to access the device. For devices using PPP, the IP address can be negotiated if the network device (e.g., router or SNMP manager) supports such negotiation. The IP address is composed of four fields with three digits per field (xxx.xxx.xxx.xxx).

The IP address is set for the COM port or the AUX port (with LAN Adapter or daisy chain), depending on which one has been chosen as the SNMP communications link. The example below assumes that an IP address of 010.155.111.222 is being set for the COM port. You can use the same principles to assign any value (between 000 and 255 for each digit field) to either port.

To assign an IP address to the COM port,

1.Press F3 to select Cnfig from the top-level menu screen.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Press F1 to select Edit.

4.Press the Setting the IP Address key from the Edit screen to display the SNMP selection.

5.Select SNMP.

Edit:

 

 

User

Alarm

SNMP

F1

F2

F3

6.Press F1 to select Gen from the SNMP Config screen.

SNMP Config:

Gen Trap

F1 F2 F3

7.Press F1 (Next) until the Com IP Adr configuration option appears.

NOTE

Steps 8 and 9 describe the process for entering an IP address. This process applies to any IP address.

8.Press F2 (Edit) to edit the IP address. You have the option of using F3 (Clear) to reset the IP address to the factory default 000.000.000.000.

Com IP Adr:

Next Edit Clear

F1 F2 F3

9.Use the Edit: and User keys to position the cursor under the digit you want to change. Press F1 (Up) to increment the digit or F2 (Down) to decrement the digit. In this example, you would press Alarm once to place the cursor under the middle digit in the first digit field, then press F1 (Up) once to change the 0 to a 1. Continue in this manner to change the other digits.

000.000.000.000

Up Down Save

F1 F2 F3

3170-A2-GB20-20