ACCULINK 317x E1 DSU/CSU

5.The following screens alternately appear on the LCD until you press a Function key to return to the Lamp Test screen. In addition, all LEDs blink.

F1 F2 F3

0123456789 : ; < = > ?

@ABCDEFGHIJKLMNO

F1 F2 F3

6.When you are satisfied that all LEDs are lighting and the LCD is functioning properly, abort the Lamp test from the Lamp Test screen. The Device Health and Status screen appears automatically if there is no activity on the E1 DSU/CSU front panel for five minutes. However, the Lamp test remains active until it is aborted.

Aborting a Lamp Test

To abort the Lamp test,

1.Display the Lamp Test screen. To do this when the LCD is alternating the Lamp test screens, press any Function key. Otherwise, follow Steps 1 through 3 for starting a Lamp test.

Lamp Test:

Abort Start

F1 F2 F3

2.From the Lamp Test screen, press F1 to select Abort.

Lamp Test:

Abort Start

F1 F2 F3

Displaying E1 DSU/CSU Test Status

Use the Test Status command to display the active tests for the E1 DSU/CSU. Status messages that can display on the front panel LCD are listed in Table 4-10.

To display test status,

1.Press F1 to select Stat from the top-level menu screen.

DSU E1 CEPT

Stat Test Cnfig

F1 F2 F3

2.From the Status screen, press the key once to display the TStat selection.

Status:

 

 

DevHS STest

Perf

F1

F2

F3

3. Press F3 to select TStat.

Status:

 

 

STest

Perf

TStat

F1

F2

F3

The Test Status screen appears showing you what tests are active for the E1 DSU/CSU.

4-24

December 1996

3170-A2-GB20-20

Page 83
Image 83
Paradyne 317x E1 manual Displaying E1 DSU/CSU Test Status, Aborting a Lamp Test, 0123456789 = ?, Status STest Perf TStat