ACCULINK 317x E1 DSU/CSU

7.Select the port from which you want to copy the configuration options using the corresponding Function key.

Copy From:

Prt1 Prt2 Prt3

F1 F2 F3

8.Select the port to which you want to copy the configuration options using the corresponding Function key. Or, press F1 (All) to choose to copy to all ports.

Copy To:

All Prt1 Prt2

F1 F2 F3

Configuring the E1 DSU/CSU for SNMP Management

To configure the E1 DSU/CSU for management by an SNMP management system you must,

Select and configure the port that provides the link to the SNMP management system.

Set the Internet Protocol (IP) address and subnet mask needed to access the device (see Appendix F, IP Network Addressing Scenario).

Select the link layer protocol (PPP or SLIP) for the port.

Specify the two community names that are allowed to access the device's Management Information Base (MIB).

Configure the device to send traps to the SNMP manager, if desired.

Selecting the Port

The SNMP manager or network device (e.g., a router) can be directly connected to the communications (COM) port. An external LAN Adapter can be connected to either the COM port or the auxiliary (AUX) port to provide Ethernet or Token Ring connectivity. Also, the E1 DSU/CSU can be daisy chained together by connecting the COM port of one device to the AUX port of the other, providing SNMP connectivity.

The COM port can support either synchronous or asynchronous PPP, or asynchronous SLIP at data rates of up to 38,400 bps. The AUX port can support data rates up to 38,400 bps.

The example shown below assumes that the COM port is being used as the link to the SNMP manager.

To select the COM port as the management link,

1.Press F3 to select Cnfig from the top-level menu screen.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Press F1 to select Edit.

4.Press the key from the Edit screen to display the User selection.

5.Select User.

Edit:

Chan Gen User

F1 F2 F3

6.Press F1 (Next) until the Com Use configuration option appears.

Self-Test:Enab

Next Enab Disab

F1 F2 F3

3-14

December 1996

3170-A2-GB20-20

Page 36
Image 36
Paradyne 317x E1 manual Configuring the E1 DSU/CSU for Snmp Management, Selecting the Port