Troubleshooting

Maintenance

Troubleshooting

problems other than those listed in the table, please

 

 

contact your service representative.

The E1 DSU/CSU is designed to provide you with

 

many years of trouble-free service. However, Table 4-6

 

gives you some direction if a problem occurs. For

 

Table 4-6

(1 of 2)

Troubleshooting

Symptom

 

Possible Cause

 

Solutions

 

 

 

 

 

No power

1.

The power cord is not securely plugged into

1.

Check that the power cord is securely

 

 

the wall receptacle or rear panel connector.

 

attached at both ends.

 

2.

The wall receptacle has no power.

2.

Check the wall receptacle power by plugging

 

 

 

 

in some equipment that is known to be

 

 

 

 

working.

 

 

 

Power-Up

The E1 DSU/CSU has detected an internal

Contact your field service representative.

Self-Test fails

hardware failure.

 

 

 

 

 

 

 

Message LOS at

1.

Network cable problem.

1.

Check that the network cable is securely

Net appears

2.

No signal is being transmitted at the far-end

 

attached at both ends.

 

 

 

 

 

E1 DSU/CSU.

2.

Check the far-end E1 DSU/CSU status.

 

3.

E1 facility problem.

3.

Contact your E1 facility provider.

 

4.

The 120 ohm interface is being used and the

4.

Change the RX SHIELD switch to the OPEN

 

 

RX SHIELD switch is in the EARTH position.

 

position when using the 120 ohm interface.

 

 

 

 

 

Message LOS at

1.

DTE Drop/Insert cable problem.

1.

Check that the DTE Drop/Insert cable is

DTE appears

2.

No signal being transmitted from the DTE.

 

securely attached at both ends.

 

2.

Check the DTE status.

 

 

 

 

 

 

 

 

Message OOF at

1.

Incompatible framing format between the

1.

Check that the framing format for the network

Net appears

 

network and the E1 DSU/CSU.

 

interface is correct.

 

2.

Network cabling problem.

2.

Check that the network cable is securely

 

3.

E1 facility problem.

 

attached at both ends.

 

3.

Contact your E1 facility provider.

 

 

 

 

 

 

 

 

Message OOF at

1.

Incompatible framing format between the

1.

Check that the framing format for the DTE

DTE appears

 

Drop/Insert port on the customer premises

 

Drop/Insert interface is correct.

 

 

equipment and the E1 DSU/CSU.

2.

Check that the DTE Drop/Insert cable is

 

 

 

 

2.

DTE Drop/Insert cabling problem.

 

securely attached at both ends.

 

 

 

 

 

Message

1.

Network cable problem.

1.

Check that your network cable is securely

RAI at Net

2.

Far-end E1 DSU/CSU DTE has detected an

 

attached at both ends.

appears

 

 

 

LOS, LOF, AIS, or EER condition.

2.

Check the status of the far-end device.

 

 

 

3.

E1 facility problem.

3.

Contact your E1 facility provider.

 

 

 

 

Message

DTE has detected an LOS, LOF, AIS, or EER

1.

Check the status of the DTE.

RAI at DTE

condition.

2.

Check that the DTE Drop/Insert cable is

appears

 

 

 

 

 

securely attached at both ends.

 

 

 

 

 

 

 

 

 

Message

1.

Upstream E1 DSU/CSU is transmitting an AIS.

1.

Check the status of the upstream E1

AIS at Net

2.

The network is transmitting an AIS.

 

DSU/CSU(s).

appears

2.

Contact your E1 facility provider.

 

 

 

 

 

 

 

 

 

 

3170-A2-GB20-20

December 1996

4-11