Maintenance

Network Performance Reports

Network performance is continuously monitored and maintained in network aggregate registers (NET) and, if configured for EDL, in far-end and near-end port registers.

Network aggregate registers (NET) are status registers that collect performance data for the previous 24-hour period. Registers shown on the front panel LCD are listed in Table 4-3. Aggregate data is updated in 15-minute intervals. After 15 minutes, the current interval is rolled over into a set of accumulator registers that represent the previous 96 15-minute intervals for the register. An interval total of how many of the 96 registers contain valid data is also kept, as well as a 24-hour total for each accumulator register.

Network port performance is continuously monitored and maintained in internal memory registers when the port interface is configured to use EDL. The E1 DSU/CSU maintains two sets of port registers for each synchronous data port: far-end port registers and near-end port registers. These registers are status registers that collect performance data for the previous 8-hour period. Registers shown on the front panel LCD are listed in Table 4-3. Port data is updated in 15-minute intervals. After 15 minutes, the current interval is rolled over into a set of accumulator registers that represent the previous 32 15-minute intervals for the register. An interval total of how many of the 32 registers contain valid data is also kept, as well as a 8-hour total for each accumulator register.

To display a network aggregate (NET) Performance Report on the front panel LCD,

1.Press F1 to select Stat from the top-level menu screen.

DSU E1 CEPT

Stat Test Cnfig

F1 F2 F3

2. From the Status screen, select Perf.

Status:

 

 

DevHS STest

Perf

F1

F2

F3

3. Select NET registers.

Performance:

NET Prt1 Prt2

F1 F2 F3

4.From the NET Registers screen, press F1 to view current registers (go to Step 5), press F2 to view 24-Hour Totals (go to Step 6), or press F3 to view 15-Minute Interval Registers (go to Step 7).

NET Registers:

Cur 24Tot Intvl

F1 F2 F3

5.When you press F1 from the NET Registers screen, the NET registers for the current 15-minute interval appear.

NET Current:

Event = xx,xxx

F1 F2 F3

6.When you press F2 from the NET Registers screen, the NET registers for the 24-hour total interval appear.

NET 24 Hour:

VldIntvl = xx

F1 F2 F3

3170-A2-GB20-20

December 1996

4-5

Page 64
Image 64
Paradyne 317x E1 manual Network Performance Reports, Performance NET Prt1 Prt2, NET Registers Cur 24Tot Intvl