This object specifies the parity used by the port. Only the following values are supported by the E1 DSU/CSU.

none(1) ± No parity bit.

odd(2) ± Odd parity. Supported on the COM port only.

even(3) ± Even parity. Supported on the COM port only.

Asynchronous Port Table, ªrs232AsyncPortAutoBaudº (rs232AsyncPortEntry 5)

This object specifies the ability to automatically sense the input speed of the port. Only the following value is supported by the E1 DSU/CSU.

disabled(2) ± Autobaud is not supported.

Synchronous Port Table, RS-232-like MIB

The synchronous port table contains an entry for each of the synchronous data ports and the COM port when the port is configured for synchronous operation. For the

E1 DSU/CSU, the entries in the table that are counters (rs232SyncPortEntry 3±7) are used to collect statistics and are not supported.

Input Signal Table ± ªrs232InSigNameº (rs232InSigEntry 2)

This object contains the identification of a hardware input signal. Only the following values are supported by the E1 DSU/CSU.

rts(1) ± Request-To-Send.

dtr(4) ± Data Terminal Ready.

Input Signal Table ± ªrs232InSigStateº (rs232InSigEntry 3)

This object contains the current signal state. Only the following values are supported by the E1 DSU/CSU.

on(2) ± The signal is asserted.

off(3) ± The signal is not asserted.

Input Signal Table ± ªrs232InSigChangesº (rs232InSigEntry 4)

This object is not supported by the E1 DSU/CSU.

Output Signal Table, RS-232-like MIB

This object contains entries for the output signals that can be asserted by the unit for each of the synchronous data ports.

Synchronous Port Table ± ªrs232SyncPortClockSourceº (rs232SyncPortEntry 2)

This object specifies the clock source for the port. Only the following values are supported by the E1 DSU/CSU.

internal(1) ± The port uses an internal clock.

external(2) ± The port uses an external clock.

Output Signal Table ± ªrs232OutSigNameº (rs232OutSigEntry 2)

This object contains the identification of a hardware output signal. Only the following values are supported by the E1 DSU/CSU.

cts(1) ± Clear-To-Send.

dsr(4) ± Data Set Ready.

Input Signal Table, RS-232-like MIB

This table contains entries for the input signals that can be detected by the unit for each of the synchronous data ports.

Output Signal Table ± ªrs232OutSigStateº (rs232OutSigEntry 3)

This object contains the current signal state. Only the following values are supported by the E1 DSU/CSU.

on(2) ± The signal is asserted.

off(3) ± The signal is not asserted.