Installation

Important Instructions

Read and follow all warning notices and instructions marked on the E1 DSU/CSU or included in this guide.

CAUTION

Disconnect the power cable before connecting or removing any data cables at the rear of the unit.

HANDLING PRECAUTIONS

FOR

STATIC-SENSITIVE DEVICES

This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative.

Optional Power Sources

The E1 DSU/CSU is typically powered by the ac power module. Use the following procedures only if you want to use an optional dc power source.

Using the optional dc power cable, the E1 DSU/CSU is capable of operating on either a +24 Vdc power source,

±48 Vdc single source battery, or ± 48 Vdc redundant source batteries (for power backup). To select the power, choose one of the following power supply types.

Installing the +24 Vdc Power Supply

To install the E1 DSU/CSU using a +24 Vdc power supply, refer to Figure 2-10 and use the following procedure.

To install the +24 Vdc power supply,

1.Connect the green wire to a suitable earth ground.

2.Connect the white wire to the +24 Vdc return.

3.Connect the orange wire to the +24 Vdc source.

4.Cut the black, red and blue wires off at the outer insulation.

5.Plug the power connector into the E1 DSU/CSU.

Figure 2-10. +24 Vdc Power Supply Pinouts