ACCULINK 317x E1 DSU/CSU

Monitoring Test Patterns on Individual Data Ports

Use the Monitor command to monitor QRSS or 511 test patterns on the channels allocated to an individual data port.

This command provides the number of errors detected in the test pattern (5 digits, maximum 99999).

To monitor a QRSS or 511 test pattern,

1.Press F2 to select Test from the top-level menu screen.

2.From the Test screen, press F3 to select Ptrns.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3. From the Patterns screen, press F3 to select Mon.

Patterns:

Abort Send Mon

F1 F2 F3

4.From the Patterns Mon screen, press F1 for QRSS or F2 for 511.

Patterns: Mon

QRSS 511

F1 F2 F3

5.From the Monitor screen, press the Function key that corresponds to the port for which you want to monitor a test pattern. Use the scroll keys, if necessary.

Monitor: Name

Prt1 Prt2 Prt3

F1 F2 F3

The Monitor screen appears with the error count. If the maximum of 99999 is exceeded, OvrFlw appears instead of the count. If the receiver loses synchronization while the monitor is active, No Sync appears.

Aborting Test Patterns

Use the Abort command to stop all test patterns or any selected test pattern active on the E1 DSU/CSU.

To abort test patterns,

1.Press F2 to select Test from the top-level menu screen.

2.From the Test screen, press F3 to select Ptrns.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3. From the Patterns screen, press F1 to select Abort.

Patterns:

Abort Send Mon

F1 F2 F3

4-22

December 1996

3170-A2-GB20-20

Page 81
Image 81
Paradyne 317x E1 manual Monitoring Test Patterns on Individual Data Ports, Aborting Test Patterns, Patterns Mon Qrss