Paradyne 317x E1 EIA 530A Port Interface Connector, Circuit, Ccitt, Mnemonic, Number, Signal

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 122
Image 122
EIA 530A Port

Pin Assignments

EIA 530A Port

Interface Connector

The EIA 530A Port Interface DB25 connector information is shown in Table D-5.

Table D-5

EIA 530A Port Interface DB25 Connector

Signal

Circuit

CCITT

Direction

Pin

Mnemonic

Number

 

 

 

 

 

 

 

 

Shield

Ð

Ð

Ð

1

 

 

 

 

 

Signal Common

AB

102A

Ð

7

 

 

 

 

 

Signal Common

AC

102B

Ð

23

 

 

 

 

 

Transmitted Data

BA

103

To DSU/CSU

2 (A)

 

 

 

 

14 (B)

 

 

 

 

 

Received Data

BB

104

From DSU/CSU

3 (A)

 

 

 

 

16 (B)

 

 

 

 

 

Request-to-Send

CA

105

To DSU/CSU

4 (A)

 

 

 

 

19 (B)

 

 

 

 

 

Clear-to-Send

CB

106

From DSU/CSU

5 (A)

 

 

 

 

13 (B)

 

 

 

 

 

Received Line Signal Detector

CF

109

From DSU/CSU

8 (A)

 

 

 

 

10 (B)

 

 

 

 

 

DCE Ready

CC

107

From DSU/CSU

6

 

 

 

 

 

DTE Ready

CD

108/1, /2

To DSU/CSU

20

 

 

 

 

 

Transmit Signal Element Timing (DTE Source)

DA

113

To DSU/CSU

11 (B)

 

 

 

 

24 (A)

 

 

 

 

 

Transmit Signal Element Timing (DCE Source)

DB

114

From DSU/CSU

12 (B)

 

 

 

 

15 (A)

 

 

 

 

 

Receiver Signal Element Timing (DCE Source)

DD

115

From DSU/CSU

17 (A)

 

 

 

 

9 (B)

 

 

 

 

 

Local Loopback

LL

141

To DSU/CSU

18

 

 

 

 

 

Remote Loopback

RL

140

To DSU/CSU

21

 

 

 

 

 

Test Mode

TM

142

From DSU/CSU

25

 

 

 

 

 

3170-A2-GB20-20

December 1996

D-7