Paradyne 317x E1 Selecting the Number of Trap Managers, Configuring a Destination for SNMP Traps

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 41
Image 41
Selecting the Number of Trap Managers

Operation

Selecting the Number of Trap Managers

If you intend to issue traps to an SNMP manager(s) from this device, you must specify the number of SNMP managers that are to receive the traps.

To specify the number of SNMP managers to receive traps from this device,

1.Press F3 to select Cnfig from the top-level menu screen.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Press F1 to select Edit.

4.Press the Num Trap Mgrs:1 key from the Edit screen to display the SNMP selection.

5.Select SNMP.

Edit:

 

 

User

Alarm

SNMP

F1

F2

F3

6. Select Trap from the SNMP Config screen.

SNMP Config:

Gen Trap

F1 F2 F3

7.Select the number of SNMP managers to receive traps (from 1 through 6) by using the appropriate Function key. Use the scroll keys, if necessary.

Num Trap Mgrs:1

 

Next 1

2

 

F1

F2

F3

Configuring a Destination for SNMP Traps

A destination must be configured for each SNMP trap manager specified. This configuration option is displayed for the number of trap managers specified by the Number of Trap Managers configuration option.

To configure an IP address for the SNMP trap manager,

1.Press F3 to select Cnfig from the top-level menu screen.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Press F1 to select Edit.

4.Press the Next 1 key from the Edit screen to display the SNMP selection.

5.Select SNMP. (For screen displays, see the previous section, Selecting the Number of Trap Managers.)

6.Select Trap from the SNMP Config screen.

7.Press F1 (Next) until the Trapn IP Address configuration option appears.

8.Press F2 (Edit) to edit the IP address. You have the option of using F3 (Clear) to reset the IP address to the factory default 000.000.000.000. Refer to the Setting the IP Address section on page 3-15 for more information on setting an IP address.

9.Press F1 (Next) until the Trapn Destination configuration appears, and select the destination for the SNMP trap by using the appropriate Function key. Use the scroll keys, if necessary.

Trapn Dst:

Next None Com

F1 F2 F3

3170-A2-GB20-20

December 1996

3-19

Page 41
Image 41
Paradyne 317x E1 Selecting the Number of Trap Managers, Configuring a Destination for SNMP Traps, Num Trap Mgrs1, Next