Paradyne 317x E1 manual Block Channel Assignment Method

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 51
Image 51
Block Channel Assignment Method

Operation

7.Select the desired port by pressing its corresponding Function key.

Channel Config:

Prt1

Prt2

Prt3

F1

F2

F3

2.Press F1 (Next) to display the next configuration option (Port Rate).

Assign By:Block

Next

Block

Chan

F1

F2

F3

8.The configuration option for the data port channel allocation destination appears on the screen. Select NET to assign this port to the Network E1 interface, select DTE to assign this port to the

DTE Drop/Insert interface, or press the Manual background key and the appropriate Function key to assign this port to another port.

Assign To:NET

Next NET DTE

F1 F2 F3

9.Press F1 (Next) to display the appropriate configuration options on the screen. Use one of the following examples, depending on whether you are assigning by block or individual channel.

Block Channel Assignment Method

The Assign By configuration option screen appears after you select a port.

To assign by the block method,

1. Press F2 (Block).

Assign By:

 

Next

Block

Chan

F1

F2

F3

3.Use the Manual background or Manual background key to scroll the desired port rate onto the screen. Rates scroll in groups of three. Available selections depend on the current base rate selected for the port. Press the corresponding Function key to select the port rate. Then, select Next to display the Start At configuration option on the screen.

Port Rate:384

Next 64 128

F1 F2 F3

4.The Start At screen displays the configuration option used to select the starting DS0 channel. If the destination selected is the Network E1 interface, then the Network channels appear on the screen. If the destination selected is the DTE Drop/Insert interface, then these channels appear on the screen.

The following screen shows an example of the

Network E1 interface. Use the Manual background or Manual background key to scroll the desired channel onto the screen. Use the Function keys to select the starting channel. Only those DS0 channel numbers that provide enough bandwidth (based on the configured data rate) to be used as a starting channel number are displayed. Channel allocation for this port can only be cleared by selecting Clear.

Start At:Clear

Next Clear N1

F1 F2 F3

3170-A2-GB20-20

December 1996

3-29

Page 51
Image 51
Paradyne 317x E1 manual Block Channel Assignment Method