DS1/E1 MIB (RFC 1406)

ACCULINK 317x E1 DSU/CSU

DS1/E1 MIB (RFC 1406)

The ªds1º object defined by RFC 1406 is supported for both the network and DTE Drop/Insert interfaces. The DS1 Near End Group and DS1 Fractional Group are supported for both interfaces. The DS1 Far End Group is not supported.

Near End Group, DS1/E1 MIB

The DS1 Near End Group consists of the following four tables:

DS1 Configuration

DS1 Current

DS1 Interval

DS1 Total

All four tables are fully supported for the network interface. Since statistics are not kept for the DTE Drop/Insert interface, only the DS1 Configuration table is fully supported. The ªstatisticº objects for the DTE Drop/Insert interface entry in the DS1 Current, DS1 Interval, and DS1 Total tables are always zero (null). The following sections provide clarification for objects contained in the Near End Group when it is not clear how the object definition in the DS1/E1 MIB is related to the E1 DSU/CSU.

Near End Group ± ªdsx1TimeElapsedº Object (dsx1ConfigEntry 3)

Applies to the network interface only. An error status is returned if access is attempted for the DTE Drop/Insert interface.

Near End Group ± ªdsx1ValidIntervalsº Object (dsx1ConfigEntry 4)

Applies to the network interface only. An error status is returned if access is attempted for the DTE Drop/Insert interface.

Near End Group ± ªdsx1LineTypeº Object (dsx1ConfigEntry 5)

This object corresponds to the NET Framing/DTE Framing configuration options for the E1 interfaces on the E1 DSU/CSU. Only the following values are supported by the E1 DSU/CSU.

dsx1E1(4) ± Indicates non-CRC-4 framing.

dsx1E1-CRC(5) ± Indicates CRC-4 framing.

Near End Group ± ªdsx1LineCodingº Object (dsx1ConfigEntry 6)

This object corresponds to the DTE Coding configuration option on the E1 DSU/CSU. Only the following values are supported by the E1 DSU/CSU.

dsx1HDB3(3) ± Indicates HDB3 line coding.

dsx1AMI(5) ± Indicates AMI line coding (for DTE only, not available for NET).

Near End Group ± ªdsx1SendCodeº Object (dsx1ConfigEntry 7)

This object specifies the test patterns/codes being sent over the network interface. These tests are not supported on the DTE Drop/Insert interface. Only the following values are supported by the E1 DSU/CSU.

dsx1SendNoCode(1) ± Specifies that the interface is sending normal or looped data. Setting the interface to this value stops an active ªsend patternº test on the interface. This is the only value supported by the DTE Drop/Insert interface.

dsx1SendOtherTestPattern(8) ± Specifies that the network interface is sending a 1-in-8 test pattern. This value is read-only. An attempt to write this value returns a badValue response.

E-8

December 1996

3170-A2-GB20-20

Page 138
Image 138