Table E-1

(2 of 3)

SNMP MIB to Front Panel Command Cross-Reference

Front Panel Command

SNMP MIB Object

Stat±>Tstat:

Read:

LLB Test Active

dsx1LineLoop from dsx1LoopbackConfig for Net E1

PLB Test Active

dsx1PayloadLoop from dsx1LoopbackConfig for Net E1

RLB Test Active

dsx1PayloadLoop from dsx1LoopbackConfig for DTE E1

DLB Test Active

dsx1LineLoop from dsx1LoopbackConfig for DTE E1

DCLB on Port n

testFullDuplexLoopback from IfExtnsTestType for Port n

DTLB on Port n

testLoopDTLB from IfExtnsTestType for Port n

1±8 Test Active

testSend1in8 from ifExtnsTestType for Net E1

QRSS on Port n

testSendQRSS from IfExtnsTestType for Port n

511 on Port n

testSend511 from IfExtnsTestType for Port n

Mon QRSS, Port n

testMonQRSS from ifExtnsTestType for Port n

Mon511, Port n

testMon511 from ifExtnsTestType for Port n

 

 

Stat±>LED±>Prtn:

Read:

DTR

rs232InSigState from rs232InSigName == dtr

CTS

rs232outSigState from rs232OutSigName == cts

RTS

rs232InSigState from rs232InSigName == rts

 

 

Stat±>ID:

 

Ser

 

Mod

Read the sysDescr object from the System Group

SRev

 

HRevCCA1

 

HRevCCA2

 

 

 

Test±>Rlpbk±>DCLBUP±>Prtn

Set IfExtnsTestType for port n to testSendV54Up

 

 

Test±>Rlpbk±>DCLBDN±>Prtn

Set IfExtnsTestType for port n to testSendV54Down

 

 

Test±>Lpbk±>LLB

Set dsx1LoopbackConfig for Net E1 to dsx1LineLoop

Test±>Lpbk±>Abort±>LLB

Set dsx1LoopbackConfig for Net E1 to dsx1NoLoop

 

 

Test±>Lpbk±>PLB

Set dsx1LoopbackConfig for Net E1 to dsx1PayloadLoop

Test±>Lpbk±>Abort±>PLB

Set dsx1LoopbackConfig for Net E1 to dsx1NoLoop

 

 

Test±>Lpbk±>DLB

Set dsx1LoopbackConfig for DTE E1 to dsx1LineLoop

Test±>Lpbk±>Abort±>DLB

Set dsx1LoopbackConfig for DTE E1 to dsx1NoLoop

 

 

Test±>Lpbk±>RLB

Set dsx1LoopbackConfig for DTE E1 to dsx1PayloadLoop

Test±>Lpbk±>Abort±>RLB

Set dsx1LoopbackConfig for DTE E1 to dsx1NoLoop

 

 

Test±>Lpbk±>DCLB±>Prtn

Set IfExtnsTestType for port n to testFullDuplexLoopBack

Test±>Lpbk±>Abort±>DCLB±>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test±>Lpbk±>DTLB±>Prtn

Set IfExtnsTestType for port n to testLoopDTLB

Test±>Lpbk±>Abort±>DTLB±>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test±>Ptrns±>Send±>QRSS±>Prtn

Set IfExtnsTestType for port n to testSendQRS

Test±>Ptrns±>Abort±>Send±>Prtn

Set IfExtnsTestType for port n to noTest

 

 

Test±>Ptrns±>Send±>1in8

Set ifExtnsTestType for Net E1 to testSend1in8

Test±>Ptrns±>Abort±>Send±>NET

Set dsx1SendCode for Net E1 to dsx1SendNoCode

 

 

3170-A2-GB20-20

December 1996

E-17

Page 147
Image 147
Paradyne 317x E1 manual Set dsx1LoopbackConfig for Net E1 to dsx1LineLoop, Set dsx1LoopbackConfig for Net E1 to dsx1NoLoop