Paradyne 317x E1 Selecting the Link Layer Protocol, Up Down Save, Com Link Next PPP SLIP, Edit

Models: 317x E1

1 167
Download 167 pages 42.72 Kb
Page 38
Image 38
010.155.111.222

ACCULINK 317x E1 DSU/CSU

10.When you are through changing the IP address, you must press F3 (Save) to save the value. Otherwise, the original value will be retained.

010.155.111.222

Up Down Save

F1 F2 F3

Selecting the Link Layer Protocol

Two link layer protocols, Point-to-Point Protocol (PPP) and Serial Line Internet Protocol (SLIP), are supported for connection to an external SNMP manager or network device (e.g., a router). PPP can be used for synchronous or asynchronous operation. SLIP can be used for asynchronous operation only.

The E1 DSU/CSU implementation of PPP supports the following:

Full negotiation of PPP's Link Control Protocol (LCP).

Active negotiation of LCP when the connection is established.

Maximum Request Unit (MRU) sizes up to

1500 bytes, but the E1 DSU/CSU will attempt to negotiate down to 500 bytes.

The E1 DSU/CSU provides a unique LCP magic number derived from the unit serial number and the elapsed time.

Full negotiation of escape characters.

The E1 DSU/CSU implementation of PPP does not support Link Quality Reports (LQR), compression, encryption, Password Authentication Protocol (PAP) or Challenge Authentication Protocol (CHAP).

The E1 DSU/CSU implementation of SLIP supports a fixed MRU size of 1006 bytes.

Before selecting the protocol, you must first select the port to be used as the communications link. Refer to the Selecting the Port section on page 3-14. This example assumes that the COM port is being used as the communications link.

To select the link layer protocol,

1.Press F3 to select Cnfig from the top-level menu screen.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Press F1 to select Edit.

4.Press the Selecting the Link Layer Protocol key from the Edit screen to display the SNMP selection.

5.Press F3 to select SNMP.

Edit:

 

 

User

Alarm

SNMP

F1

F2

F3

6.Press F1 to select Gen from the SNMP Config screen.

SNMP Config:

Gen Trap

F1 F2 F3

7.Press F1 (Next) until the Com Link configuration option appears.

8.Press F2 (PPP) or F3 (SLIP).

Com Link:

Next PPP SLIP

F1 F2 F3

3-16