Starting Front Panel

ACCULINK 317x E1 DSU/CSU

Starting Front Panel

Emulation

If the E1 DSU/CSU selected is not locally attached to the PC, you must first dial to the remote E1 DSU/CSU before starting front panel emulation. The modem attached to the PC must support AT commands for the Front Panel Emulation software to successfully place the call.

To start front panel emulation,

1.From the PC, open Program Manager from Windows.

2. The Front Panel Window opens.

3.Double click on the Front Panel icon that appears after the Front Panel Emulation program is installed on the PC. The Front Panel Emulation screen appears.

4.Enter the Com Port and Speed from the drop-down selection list boxes.

The Com Port field needs to contain the actual communications port name as recorded in the Windows information file (INI).

The Speed field needs to contain one of the following communications speeds: 1200, 2400, 4800, 9600, 14400, 19200, or 38400 and should match the DSU/CSU COM port configuration.

5.Choose either a Local (for near-end E1 DSU/CSU) or Remote (for far-end E1 DSU/CSU) destination.

6.If you chose a Local destination, click on the Execute button. If you chose a Remote destination, enter the telephone number of the external modem connected to the far-end E1 DSU/CSU in the Phone Number field, then click on the Dial button.

7.The front panel of the selected E1 DSU/CSU appears on the PC.

NOTE

When using Front Panel Emulation, no LEDs are shown on the PC's screen; you must use the Stat command procedure to get LED information (see the Displaying LED Conditions section in Chapter 3, Operation).