Table C-10

(2 of 2)

SNMP Trap Configuration Options

Entp Trap: Enab

Next Enab Disab Prev

Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled. For more information, refer to the SNMP Traps section in Chapter 4, Maintenance.

Enab ± Sends trap messages for enterpriseSpecific events to the currently configured trap manager(s).

Disab ± Disables the sending of trap messages for enterpriseSpecific events.

NOTE: This configuration option is not available and does not appear if the SNMP Trap configuration option (in the Alarm Configuration Options section) is disabled.

Link Trap: Both

Next Disab Up Down Both Prev

Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp and linkDown traps can be specified with the Trap I/F configuration option. For more information, refer to the SNMP Traps section in Chapter 4, Maintenance.

Disab ± Disables the sending of trap messages for linkDown or linkUp events.

Up ± Sends trap messages for linkUp events to the currently configured trap manager(s).

Down ± Sends trap messages for linkDown events to the currently configured trap manager(s).

Both ± Sends trap messages for linkUp and linkDown events to the currently configured trap manager(s).

NOTE: This configuration option is not available and does not appear if the SNMP Trap configuration option (in the Alarm Configuration Options section) is disabled.

Trap I/F: All

Next NET DTE E1s Ports All Prev

Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap messages. These traps are supported on the E1 interfaces (network and DTE Drop/Insert) and the synchronous data ports.

NET ± Sends trap messages for linkUp and linkDown events occurring on the network interface.

DTE ± Sends trap messages for linkUp and linkDown events occurring on the DTE Drop/Insert interface. This selection is not displayed if the DTE Drop/Insert interface is disabled.

E1s ± Sends trap messages for linkUp and linkDown events occurring on either the network or DTE Drop/Insert interface.

Ports ± Sends trap messages for linkUp and linkDown events occurring on the synchronous data ports.

All ± Sends trap messages for linkUp and linkDown events occurring on the network interface, DTE Drop/Insert interface, or the synchronous data ports.

NOTE: This configuration option is not available and does not appear if the Link Trap configuration option is not configured to generate trap messages for linkUp or linkDown events.