Traps
E-4 8000-A2-GB20-20November 1997
RTU Related Traps
The RTUs send the following traps. For a listing of Paradyne Enterprise MIBS,
see Chapter 8 of the
Hotwire DSLAM for 8540 and 8546 DSL Cards Network
Configuration Guide.

Standard Traps

Event Trap Class Comment
Authentication Failure minor Community string used is not in the
Community Table.
Use of read only community string for Set
PDU.
Warm start warning RTU has been reset by an NMS.

Enterprise-Specific Traps

Event Trap Class Comment
Enterprise device failure major Operating software has detected an internal
device failure. The RTU is still operating.
Enterprise selftest failure minor Failure of the RTU’s hardware components.
This trap is only sent if the hardware failure
still allows sending traps.
Enterprise fatal reset major Variable-bindings field contains device
failure code.
RTU device mismatch
(Sent by the DSL card)
minor RTU identified on port N does not match
device described in port configuration table.
RTU device mismatch
(Sent by the DSL card)
normal RTU identified on port N now matches
device described in port configuration table.