Traps

RTU Related Traps

The RTUs send the following traps. For a listing of Paradyne Enterprise MIBS, see Chapter 8 of the Hotwire DSLAM for 8540 and 8546 DSL Cards Network Configuration Guide.

Standard Traps

Event

Trap Class

Comment

 

 

 

Authentication Failure

minor

H Community string used is not in the

 

 

Community Table.

 

 

H Use of read only community string for Set

 

 

PDU.

 

 

 

Warm start

warning

RTU has been reset by an NMS.

 

 

 

Enterprise-Specific Traps

Event

Trap Class

Comment

 

 

 

Enterprise device failure

major

Operating software has detected an internal

 

 

device failure. The RTU is still operating.

 

 

 

Enterprise selftest failure

minor

Failure of the RTU's hardware components.

 

 

This trap is only sent if the hardware failure

 

 

still allows sending traps.

 

 

 

Enterprise fatal reset

major

Variable-bindings field contains device

 

 

failure code.

 

 

 

RTU device mismatch

minor

RTU identified on port N does not match

(Sent by the DSL card)

 

device described in port configuration table.

 

 

 

 

 

RTU device mismatch

normal

RTU identified on port N now matches

(Sent by the DSL card)

 

device described in port configuration table.

 

 

 

 

 

E-4

November 1997

8000-A2-GB20-20

Page 147
Image 147
Paradyne 8540, 8546 manual RTU Related Traps, Standard Traps, Enterprise-Specific Traps