Traps

The MCC card sends the following traps.

Event

Trap Class

Comment

Device failure

major

Ð

 

 

 

Self test failure

minor

Sent if any portion of a restart or selftest

 

 

fails.

 

 

 

CCN (Configuration

warning

Configuration changed or software

Change Notice)

 

upgraded.

 

 

 

Entity MIB CCN

warning

Configuration changed due to differences

(Configuration Change

 

affecting Entity MIB.

Notice)

 

 

 

 

 

Authentication failure

minor

SNMP community string mismatches.

 

 

 

Authentication failure

minor

Telnet and terminal password mismatches.

 

 

This trap may be overloaded for terminal

 

 

and Telnet based auth failures. In these

 

 

cases the following will also be sent along

 

 

with the trap PDU:

 

 

Ð Access mode used

 

 

Ð Number of auth failures

 

 

For SNMP based auth failures, no

 

 

information will be sent.

 

 

 

Fan module failure

major

Fan module reporting subnormal

 

 

performance.

 

 

 

Fan module operational

normal

Fan module back to normal operation.

 

 

 

A power source failure

minor

Power source A has failed and the system is

 

 

now operating off one source.

 

 

 

A power source normal

normal

Power source A is now operating normally.

 

 

 

B power source failure

minor

Power source B has failed and the system is

 

 

now operating off one source.

 

 

 

B power source normal

normal

Power source B is now operating normally.

 

 

 

Ethernet link down

major

Ð

 

 

 

Ethernet link up

normal

Ð

 

 

 

Slot poll failure

major

No response to slot poll. Responds to

 

 

hardware MIP query, but not general poll.

 

 

 

New card detected

warning

New card detected by MCC on slot poll.

 

 

 

Cold start

warning

MCC card is being powered up.

 

 

 

Warm start

warning

Power on reset.

 

 

 

8000-A2-GB20-20

November 1997

E-3

Page 146
Image 146
Paradyne 8546, 8540 manual Traps MCC card sends the following traps