5446 RTU Setup

"Procedure

From an SNMP workstation:

1.To load the MIB, access the Paradyne World Wide Web site: http://www.paradyne.com

2.Select:

Service & Support MIBs HotWire DSL pdndce.mib

3.Enter the IP address of the RTU.

4.Press Options to change Set Community to Private.

5.Locate the MIB group pdn-ipinjection.

From a MIB browser, do a single set with a unique entry containing the required fields. Refer to Table F-1for IP injection group objects.

Using the null entry:

"Procedure

1.Change the Null entry by entering the IP address (ipInjectionAddress).

2.Change the mask by entering a subnet mask (ipInjectionMask).

3.Change the Type to Service Provider or Host (ipInjectionType).

4.Select Set.

5.Do a Get or Query to verify before continuing to the next entry.

Using the table index:

"Procedure

1.Enter the three fields into the Index:

ÐipInjectionType

ÐipInjectionAddress

ÐipInjectionMask

2.Enter the status value:

ÐipInjectionStatus

3.Select Set.

If a null entry does not appear, the table is full. Delete entries from the table by setting the ipInjectionStatus to invalid.

F-4

November 1997

8000-A2-GB20-20

Page 151
Image 151
Paradyne 8540, 8546 manual Using the null entry