MCC Card Configuration
Table 5-1. Card Status Menu Options (3 of 3)
Card Reset (Reset System) | |
|
|
Gives the user the ability to reset the card. This resets all counters and if a new configuration or software version has been downloaded, the new code will then become active.
Reset Card ± Enter Yes to reset card.
NOTE: This action disrupts the data flow for at least 10 seconds.
Download Code (Download Code and Apply Download) | |
|
|
Gives the user the ability to download a new version of code and apply the downloaded code. For further information on this feature, see Appendix C, Download Code and Apply Download.
Download Code | A |
|
|
This screen is similar to the NVRAM Config Loader screen.
Image File Name ± The file name may be a regular pathname expression of directory names separated by a forward slash (/) ending with the file name. The total pathname length must be less than 40 characters. If the TFTP server is hosted by a DOS machine, then directory and file names must follow the 8.3 naming convention imposed by DOS.
TFTP Server IP Address ± nnn.nnn.nnn.nnn format.
Start Transfer ± Yes/No (Default = No).
Packets Sent ± Number of packets sent in download.
Packets Received ± Number of packets received in download.
Bytes Sent ± Number of bytes sent in download.
Bytes Received ± Number of bytes received in download.
Transfer Status ± Status of the download transfer.
Once the download is complete, press
Apply Download | B |
|
|
This selection applies the downloaded code and drops all connections by performing a device reset. This screen is used to overlay the previously downloaded image for the card. If you select yes at the Reset System prompt, the system goes through a system restart and interrupts service on the card. For further information on this feature, see Appendix C, Download Code and Apply Download.
NOTE: If you have not previously downloaded code, then you will not be able to access this selection.