Configuring an M1 CPU with Modsoft
Setting the Time
Overview | Once you have reserved a block of registers for the | |
| set the correct time. Modsoft offers two ways to do this: | |
| λ | using the Set Hardware Clock dialogue |
| λ | setting the register bits individually |
Note: The
Option 1 | You must be online or in combined mode to access the Set Hardware Clock | ||
| dialogue. | ||
|
|
|
|
| Step | Action |
|
|
|
|
|
| 1 | From the PlcOps menu, select Set Hardware Clock. |
|
|
| Result: The Set Hardware Clock dialogue appears. |
|
|
|
|
|
| 2 | You may set the time directly or copy the current time setting from your |
|
|
| programming panel. |
|
|
| lTo set the time directly, proceed to step 3. |
|
|
| To copy the setting from your programming panel, proceed to step 4. |
|
|
|
|
|
| 3 | The time setting for your programming panel is displayed on the left. The |
|
|
| controller time setting is displayed on the right. The time is expressed as |
|
|
| hh:mm:ss. The date is expressed as |
|
|
| To modify the settings, type a new value in the date or time field for the |
|
|
| lcontroller. |
|
|
| To confirm the default settings or your modified settings, press <Enter>. |
|
|
|
|
|
| 4 | To copy the current time setting from your programming panel, type Y in response |
|
|
| to the question: Write PANEL clock data to PLC? (Y/N). Then |
|
|
| press <Enter>. |
|
|
|
|
|
|
|
|
|
|
| Continued on next page | |
228 | 870 USE 101 10 V.2 |