Overview of Momentum M1 Processor Adapters
171 CCC 780 10, Continued
Specifications, |
|
|
Mechanical |
| |
Continued |
| |
|
| |
| Weight | 42.5 g (1.5 oz.) |
|
|
|
| Dimensions (HxDxW) | 25.9x61.02x125mm |
|
| (1.01 x 2.37 x 4.86 in) |
|
|
|
| Material (Enclosures/ | Lexan |
| bezels) |
|
|
|
|
| Operating Conditions |
|
|
|
|
| Temperature | 0 ... 60 degrees C |
|
|
|
| Humidity | 5 ... 95% (noncondensing) |
|
|
|
| Chemical interactions | Enclosures and bezels are made of Lexan, |
|
| a polycarbonate that can be damaged by strong |
|
| alkaline solutions |
|
|
|
| Altitude, full operation | 2000m (6500ft) |
|
|
|
| Vibration | 10 ... 57Hz @ 0.075mm displacement amplitude |
|
| 57...150Hz @ 1g |
|
| Ref. IEC |
|
|
|
| Shock | |
|
| Ref. IEC |
|
|
|
| RFI Susceptibility/ | Meets CE mark requirements for open equipment. |
| immunity | Open equipment should be installed in an industry- |
|
| standard enclosure, with access restricted to qualified |
|
| service personnel. |
|
|
|
| Storage Conditions |
|
|
|
|
| Temperature | |
|
|
|
| Humidity | 5 ... 95% (noncondensing) |
|
|
|
| Safety Parameters |
|
|
|
|
| Degree of protection | Unintentional access (UL 508 Type 1, NEMA250 Type 1, |
|
| IP20 conforming to IEC529) |
|
|
|
| RS232 and RS485 are | |
|
|
|
| Ground continuity | 30 A test on the exposed metal connector |
|
|
|
| Agency Approvals | lUL 508, CSA, CUL, CE |
|
| FM class1, div2 |
|
|
|
46 | 870 USE 101 10 V.2 |