Specifications

Specifications

Note: Siemens Milltronics makes every attempt to ensure the accuracy of these specifications, but reserves the right to change them at any time.

SITRANS LR 460

Power

Power Supply

100 to 230 V AC, ±15%, 50/60 Hz, 6 W

24 V DC, +25/-20%, 6 W

Fuse (AC)

SI1

Fast acting ceramic, 4 x 20 mm, 1 A, 250 V AC

 

 

SI2

Slow-Blow, 4 x 20 mm, 0.63 A, 250 V AC

Fuse (DC)

SI1

Fast acting ceramic, 4 x 20 mm, 2 A, 250 V AC

 

 

SI2

Slow-Blow, 4 x 20 mm, 0.63 A, 250 V AC

Performance

Reference operating conditions according to IEC 60770-1

ambient temperature

+15 to +25 oC

humidity

45 to 75% relative humidity

ambient pressure

860 to 1060 mbar (12.47 to 15.37 psi)

Measurement Accuracy (measured in accordance with IEC 60770-1)

non-linearity (accuracy)

greater of 25 mm (1”) or 0.25% of span (including

 

 

hysteresis and non-repeatability)

non-repeatability

10 mm (0.4”) [included in non-linearity specification]

deadband (resolution)

10 mm (0.4”) [included in non-linearity specification]

hysteresis error

0 mm

Analog Output Accuracy (measured in accordance with IEC 60770-1)

non-linearity (accuracy)

0.100% of span (including hysteresis and repeatability)

non-repeatability

0.030% of span (included in non-linearity specification)

deadband (resolution)

0.030% of span [included in non-linearity specification]

hysteresis error

0%

Frequency

25 GHz nominal

Measurement range1

0.35 to 100 m (1.15 to 328.08 ft).

1.Referenced from flange face.

Page 6

SITRANS LR 460 – INSTRUCTION MANUAL

7ML19985JM01

Page 12
Image 12
Siemens LR 460 instruction manual Specifications, Power, Performance