Hazardous area installations
Product Nameplate
Note: The nameplate shown is a typical example. Please check the nameplate on your device for your specific device configuration.
SITRANS LR 460 Radar Level Meter
Serial # GYZ/S1034567 | 0518 | |
0891 | ||
Power Rating:100 - 230 V , ±15%, 50/60 Hz, 6 W | ||
Enclosure: | TYPE/NEMA 4X, 6 / IP67 | Canada |
Amb. Temp.: – 40°C to 65°C | II 1D, 1/2 D, 2D | |
|
| |
Output: | 4 - 20 mA HART | Ex tD A20 IP67 T85°C |
|
| SIRA 06ATEX9218X |
IECEx SIR 06.0058X
Ex tD A20 IP67 T85°C
Do Not Open in an explosive dust atmosphere.
Siemens Milltronics Process Instruments Inc., Peterborough
Made in Canada
Instructions specific to hazardous area installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
Note: Installation shall be performed only by qualified personnel and in accordance with local governing regulations.
The following instructions apply to equipment covered by certificate number Sira 06 ATEX 9218X.
1.For use and assembly, refer to the main instructions.
2.The equipment is certified for use as Category II 1D, 1/2 D & 2D equipment. The Essential Health and Safety Requirements are assured by compliance with IEC
3.The equipment may be used with dust and fibers with apparatus temperature class T (see table below).
mmmmm Wiring
7ML19985JM01 | SITRANS LR 460 – INSTRUCTION MANUAL | Page 23 |