Appendix D: Local Operation Interface

The LCD Display

Note: SITRANS LR 460 continues to monitor In and Out values even when the device is in PROGRAM mode.

RUN mode (startup display)

Normal operation

1

2

3

5

 

4

98.82 m

5

3.800 mA

 

LOE condition

1

2

3

4

98.82 m S: 0

1 – Primary display: level, space, or distance

2 – Units: for Primary Value (m, cm, mm, ft, in, or percent) if applicable

3 – Echo status indicator:

Reliable Echo:

 

 

 

visible during normal operation.

 

 

 

 

 

 

 

 

 

 

 

Unreliable Echo: If LOE is pending1 the x flashes, alternating with the two horizontal bars.

When LOE becomes active, the x becomes solid and the auxiliary display shows fault code S: 0.

4 – Heartbeat: a small heart-shaped icon flashes on and off once per second.

5 – Auxiliary display2: distance, mA value (HART only), confidence, or temperature.

PROGRAM Mode Display

1

 

 

1

– Menu level

 

2

– Parameter name

 

3

– Edit Mode indicator/PROGRAM icon

4

4

– Value of current parameter

 

23

1.3.1 SOFT REV 0.01.18

D: Local Interface

1.See LOE Timer on page 74 for details.

2.Appears in response to request via Siemens Milltronics handheld programmer

7ML19985JM01

SITRANS LR 460 (HART) – INSTRUCTION MANUAL

Page D-85

Page 91
Image 91
Siemens LR 460 instruction manual LCD Display, RUN mode startup display, Program Mode Display, Local Interface