LOOP - Local Loopback. When set, transmit frames are internally looped to the receiver after the encoder/decoder. Collision and Carrier Sense are ignored. No data is sent out. Defaults low to normal mode.
TXENA - Transmit enabled when set. Transmit is disabled if clear. When the bit is cleared, the SMC91C95 will complete the current transmission before stopping. When stopping due to an error, this bit is automatically cleared.
|
|
|
|
|
| TRANSMITS |
AUI | FDSE | FDUPLX | EPH_LOOP | LOOP | LOOPS AT | TO |
|
|
|
|
|
| NETWORK |
|
|
|
|
|
|
|
X | X | X | 1 | X | EPH Block | No |
|
|
|
|
|
|
|
X | X | 1 | 0 | 1 | ENDEC | No |
|
|
|
|
|
|
|
1 | 0 | 1 | 0 | 0 | Cable | Yes |
|
|
|
|
|
|
|
0 | 0 | 1 | 0 | 0 | Yes | |
|
|
|
|
|
|
|
X | 0 | 0 | 0 | 0 | Normal CSMA/CD - No | Yes |
|
|
|
|
| Loopback |
|
|
|
|
|
|
|
|
X | 1 | 1 | 0 | 0 | Full Duplex Switched | Yes |
|
|
|
|
| Ethernet - No loopback |
|
|
|
|
|
| and no SQET |
|
|
|
|
|
|
|
|
41