104
OPERATIONAL DESCRIPTION
MAXIMUM GUARANTEED RATINGS*
Operating Temperature Range...................................................................................... 0 o C to +70o C
Storage Temperature Range .................................................................................... -55o C to +150o C
Lead Temperature Range (soldering, 10 seconds) ..................................................................+325o C
Positive Voltage on any pin, with respect to Ground ...........................................................Vcc + 0.3V
Negative Voltage on any pin, with respect to Ground .................................................................. -0.3V
Maximum Vcc ............................................................................................................................... +7V
*Stresses above those listed above could cause permanent damage to the device. This is a stress
rating only and functional operation of the device at any other condition above those indicated in the
operation sections of this specification is not implied.
Note: When powering this device from laboratory or system power supplies, it is important that the
Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies
exhibit voltage spikes on their outputs when the AC power is switched on or off. In addition, voltage
transients on the AC power line may appear on the DC output. If this possibility exists, it is
suggested that a clamp circuit be used.
DC ELECTRICAL CHARACTERISTICS (TA = 0o C - 70o C, Vcc = +5.0 V ± 10%)
PARAMETER SYMBO
LMIN TYP MAX UNITS COMMENTS
I Type Input Buffer
Low Input Level
High Input Level
VILI
VIHI 2.0
0.8 V
V
TTL Levels
IS Type Input Buffer
Low Input Level
High Input Level
Schmitt Trigger Hysteresis
VILIS
VIHIS
VHYS
2.2
250
0.8 V
V
mV
Schmitt Trigger
Schmitt Trigger
ICLK Input Buffer
Low Input Level
High Input Level
VILCK
VIHCK 3.0
0.4 V
V