t51

 

t52

A0-9,A15

valid

 

t47

 

t49

nREG

 

 

t48

 

t50

nCE1,nCE2

 

 

 

 

t20

 

t54

t55

nIOWR

 

 

D0-15

valid

 

 

Parameter

min

typ

max

units

 

 

 

 

 

 

t47

nREG Low Setup to Control Active

5

 

 

ns

t48

nCE1,nCE2 Setup to Control Active

5

 

 

ns

t49

nREG Hold after Control Inactive

0

 

 

ns

t50

nCE1,nCE2 Hold after Control Inactive

15

 

 

ns

t51

Address Setup to Control Active

25

 

 

ns

t52

Address Hold after Control Inactive

15

 

 

ns

t20

Cycle Time (No Wait States)

185

 

 

ns

t54

Write Data Setup to nIOWR Rising

30

 

 

ns

t55

Write Data Hold after nIOWR Rising

9

 

 

ns

 

 

 

 

 

 

FIGURE 24 - CONSECUTIVE PCMCIA WRITE CYCLES

116

Page 116
Image 116
SMC Networks SMC91C95 manual Consecutive Pcmcia Write Cycles, 116