Texas Instruments MSP50C614 manual ±3. Reset Circuit

Models: MSP50C614

1 414
Download 414 pages 24.44 Kb
Page 25
Image 25

C605 and C604 (Preliminary Information)

Figure 1±3. RESET Circuit

(MSP50P614 only)

VPP

IN914³

To Pin 1 of Optional (Scanport) Connector

5 V

Inside the

MSP50P614

MSP50C614

VDD

 

100 kΩ

RESET

1 kΩ²

 

 

1 F

 

(20%)

IN914

Reset

Switch

To Pin 2 of optional (scan port) connector²

VSS

²If it is necessary to use the software development tools to control the MSP50P614 in application board, the 1 kΩ resistor is need- ed to allow the development tool to over drive the RESET circuit on the application board.

³This Diode can be omitted (shorted) if the application does not require use of the scanport interface. See Section 7.1.1 regarding scan port bond out.