MDIO Registers

www.ti.com

4MDIO Registers

Table 22 lists the memory-mapped registers for the MDIO module. See your device-specific data manual for the memory address of these registers.

Table 22. Management Data Input/Output (MDIO) Registers

Offset

Acronym

Register Description

Section

0h

REVID

MDIO Revision ID Register

Section 4.1

4h

CONTROL

MDIO Control Register

Section 4.2

8h

ALIVE

PHY Alive Status register

Section 4.3

Ch

LINK

PHY Link Status Register

Section 4.4

10h

LINKINTRAW

MDIO Link Status Change Interrupt (Unmasked) Register

Section 4.5

14h

LINKINTMASKED

MDIO Link Status Change Interrupt (Masked) Register

Section 4.6

20h

USERINTRAW

MDIO User Command Complete Interrupt (Unmasked) Register

Section 4.7

24h

USERINTMASKED

MDIO User Command Complete Interrupt (Masked) Register

Section 4.8

28h

USERINTMASKSET

MDIO User Command Complete Interrupt Mask Set Register

Section 4.9

2Ch

USERINTMASKCLEAR

MDIO User Command Complete Interrupt Mask Clear Register

Section 4.10

80h

USERACCESS0

MDIO User Access Register 0

Section 4.11

84h

USERPHYSEL0

MDIO User PHY Select Register 0

Section 4.12

88h

USERACCESS1

MDIO User Access Register 1

Section 4.13

8Ch

USERPHYSEL1

MDIO User PHY Select Register 1

Section 4.14

 

 

 

 

4.1MDIO Revision ID Register (REVID)

The MDIO revision ID register (REVID) is shown in Figure 25 and described in Table 23.

Figure 25. MDIO Revision ID Register (REVID)

31

0

REV

R-0007 0104h

LEGEND: R = Read only; -n= value after reset

Table 23. MDIO Revision ID Register (REVID) Field Descriptions

Bit

Field

Value

Description

 

 

 

 

31-0

REV

 

Identifies the MDIO Module revision.

 

 

0007 0104h

Current revision of the MDIO Module.

 

 

 

 

70

EMAC/MDIO Module

SPRUFL5B –April 2011

 

 

Submit Documentation Feedback

© 2011, Texas Instruments Incorporated

Page 70
Image 70
Texas Instruments TMS320C674X manual Mdio Revision ID Register Revid, Management Data Input/Output Mdio Registers