Texas Instruments TMS320C674X manual Receive Maximum Length Register RXMAXLEN

Models: TMS320C674X

1 136
Download 136 pages 20.2 Kb
Page 107
Image 107
5.24 Receive Maximum Length Register (RXMAXLEN)

www.ti.com

EMAC Module Registers

5.24 Receive Maximum Length Register (RXMAXLEN)

The receive maximum length register (RXMAXLEN) is shown in Figure 62 and described in Table 61.

 

Figure 62. Receive Maximum Length Register (RXMAXLEN)

31

16

 

 

 

Reserved

 

 

 

R-0

15

0

 

 

 

RXMAXLEN

 

 

R/W-5EEh

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Table 61. Receive Maximum Length Register (RXMAXLEN) Field Descriptions

Bit

Field

Value

Description

 

 

 

 

31-16

Reserved

0

Reserved

 

 

 

 

15-0

RXMAXLEN

0-FFFFh

Receive maximum frame length. These bits determine the maximum length of a received frame.

 

 

 

The reset value is 5EEh (1518). Frames with byte counts greater than RXMAXLEN are long

 

 

 

frames. Long frames with no errors are oversized frames. Long frames with CRC, code, or

 

 

 

alignment error are jabber frames.

 

 

 

 

5.25 Receive Buffer Offset Register (RXBUFFEROFFSET)

The receive buffer offset register (RXBUFFEROFFSET) is shown in Figure 63 and described in Table 62.

 

Figure 63. Receive Buffer Offset Register (RXBUFFEROFFSET)

31

16

 

 

 

Reserved

 

R-0

15

0

RXBUFFEROFFSET

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Table 62. Receive Buffer Offset Register (RXBUFFEROFFSET) Field Descriptions

Bit

Field

Value

Description

 

 

 

 

31-16

Reserved

0

Reserved

 

 

 

 

15-0

RXBUFFEROFFSET

0-FFFFh

Receive buffer offset value. These bits are written by the EMAC into each frame SOP

 

 

 

buffer descriptor Buffer Offset field. The frame data begins after the RXBUFFEROFFSET

 

 

 

value of bytes. A value of 0 indicates that there are no unused bytes at the beginning of

 

 

 

the data, and that valid data begins on the first byte of the buffer. A value of Fh (15)

 

 

 

indicates that the first 15 bytes of the buffer are to be ignored by the EMAC and that valid

 

 

 

buffer data starts on byte 16 of the buffer. This value is used for all channels.

 

 

 

 