Texas Instruments TMS320DM643x manual Internal Peripherals, Interrupt Controller INTC

Models: TMS320DM643x

1 98
Download 98 pages 20.5 Kb
Page 22
Image 22
2.4Internal Peripherals

www.ti.com

Internal Peripherals

2.4Internal Peripherals

This C64x+ Megamodule includes the following internal peripherals:

Interrupt controller (INTC)

Power-down controller (PDC)

This section briefly describes the INTC and PDC. For more information on these peripherals, see the TMS320C64x+ DSP Megamodule Reference Guide (SPRU871).

2.4.1 Interrupt Controller (INTC)

The C64x+ Megamodule includes an interrupt controller (INTC) to manage CPU interrupts. The INTC maps the 0 to 127 DSP device events to 12 CPU interrupts. Refer to device-specific data manual for a list of all the DSP device events. The interrupt controller section of the TMS320C64x+ DSP Megamodule Reference Guide (SPRU871) fully describes the INTC and how it maps the DSP device events to the 12 CPU interrupts.

2.4.2 Power-Down Controller (PDC)

The C64x+ Megamodule includes a power-down controller (PDC). The PDC can power-down all of the following components of the C64x+ Megamodule:

C64x+ CPU

L1P controller

L1D controller

L2 controller

Extended memory controller (EMC)

Internal direct memory access (IDMA) controller

The DM643x DMP does not support power-down of the internal memories of the DSP subsystem.

The C64x+ Megamodule is capable of providing both dynamic and static power-down; however, only static power-down is supported on the DM643x DMP. The TMS320C64x+ DSP Megamodule Reference Guide (SPRU871) describes the power-down control in more detail.

Static power-down: The PDC initiates power down of the entire C64x+ Megamodule and all internal memories immediately upon command from software.

On the DM643x DMP, static power-down affects all components of the C64x+ Megamodule. The DM643x DMP does not support power-down of the internal memories. Software can initiate static power-down via a register bit in the PDC register. For more information on the PDC, see the TMS320C64x+ DSP Megamodule Reference Guide (SPRU871).

Note: The DM643x DMP does not support dynamic power-down.

22

TMS320C64x+ Megamodule

SPRU978E–March 2008

Submit Documentation Feedback

Page 22
Image 22
Texas Instruments TMS320DM643x manual Internal Peripherals, Interrupt Controller INTC, Power-Down Controller PDC