6F8A0917

Range switching output One Digital Output (DO) is used

Single direction, 2-range switching signal

Forward/reverse direction switching signal

Two Digital Outputs (DO) are used

Single direction, 4-range switching signals

Forward/reverse 2-range switching signals

High/low limit alarm output

An alarm is output when flow rate goes above or below the set-point value

Setting range 10 to 110% of the settable maximum range High limit 2 points, low limit 2 points can be set

At the time of alarm output, Normally Open or Normally Closed contact can be selected

Preset counter output

Contact ON when totalizer count exceeds the set value

Setting range 1 to 99999999 count

Converter error alarm

An alarm is output when an operation error is detected by self-diagnosis.

At the time of alarm output, Normally Open or Normally Closed contact can be selected

Digital Input (option: added when 9th digit of specification code is “3”): 2 Digital Inputs

Signal type:

Voltage signal of 20 to 30 VDC (H level: 20 to 30 VDC, L level: 2 VDC :

 

or less)

Input resistance: About 2.7 kΩ

*For digital input function, either of the following functions can be selected. Digital Input function

Range switching input

One Digital Input is used: switching between large and small ranges

 

of forward/reverse, 2-range measurement

 

Two Digital Inputs are used: switching between ranges of single

Totalizer control input

direction, 4-range measurement

Totalizer Start/Stop control or Reset/Start

Output hold input

Fixed with set value for current output and pulse output (loop check)

Zero adjustment input

Performs still water zero adjustment

4.Communication function

Communication signal: Digital signal is superimposed on 4 to 20mA signal line (conforms to

HART*1 protocol)

Load resistance 240Ω to 1kΩ

Load capacitance 0.25μF or less

Load inductance 4mH or less

(For maximum cable length, about 2km is a guideline length when CVV-S 1.25mm2 is used under standard installation condition.)

*1 HART: “HART” stands for Highway Addressable Remote Transducer and is the name of the communication protocol for industry sensors that is recommended by HCF (HART Communication Foundation).