6F8A0917

Digital Input Function

DI FUNCT.

 

Digital input function

 

 

 

1: NO USE

Not used

 

 

 

 

2: C STA/STP

Totalizer

Start/Stop control

 

 

 

3: C RES/STA

Totalizer

Reset/Start control

 

 

4: RANGE SW1

Multi-range external switching signal 1

 

 

5: ZERO ADJ

Still water zero adjustment start

 

 

6: FIXED OUT

Fixed-value output mode control

 

 

7: RANGE SW2

Multi-range external switching signal 2

 

 

 

Level setting for digital input control signal (for totalizer control only)

For totalizer control (items indicated byabove), the operating level (active level) for input control signal can be selected for each DI terminal.

DI DET LEVEL

Control signal level

 

 

1: L LEVEL

Low level active

 

 

2: H LEVEL

High level active

 

 

The operation for control signal input is shown below depending on the active level setting.

Digital input function setting

Control signal

Operation when control signal is input

level setting

 

 

 

 

 

 

L LEVEL

High signal: Totalization Stop

CNT STA/STP

Low signal: Totalization Start

 

(Totalizer Start/Stop)

 

 

H LEVEL

High signal: Totalization Start

 

Low signal: Totalization Stop

 

 

 

 

 

 

L LEVEL

High signal: Totalization Start

CNT RES/STA

Low signal: Totalization Reset

 

(Totalizer Reset/Start)

 

 

H LEVEL

High signal: Totalization Reset

 

Low signal: Totalization Start

 

 

 

 

 

- 90 -

Page 91
Image 91
Toshiba L5232 manual Digital Input Function