Checking the count rate and pulse width

How to check the count rate setting is shown below.

To check other setting values, select the following function numbers:

Pulse width mode

H2: PLS MODE

Pulse width

H3: PLS WIDTH

 

 

 

Switch operation

Display example

Description

 

 

 

H1: COUNT RATE

Select H1: COUNT RATE from the setting item selection

menu.

1.00000 m3

The currently set count rate appears.

 

 

H1: COUNT RATE

Returns to the menu of setting item selection.

Changing the count rate

The following is an example to change the count rate from 0.01m3 to 200 l (liter).

Switch operation

Display example

 

 

 

 

Description

 

 

 

 

 

 

 

H1: COUNT

RATE

Select H1: COUNT RATE from the setting item selection

 

menu.

 

 

 

 

1.00000

m3

 

 

 

 

The currently set count rate appears.

 

 

 

 

 

 

 

 

 

 

H1: COUNT

RATE

The cursor appears.

 

1.00000

m3

Press

further to move the cursor to the digit of unit.

 

 

 

 

 

 

 

H1: COUNT

RATE

Change the unit to l.

 

1000.00

l

Then press

to move the cursor to the desired digit to change

 

 

and change the number there. Repeat this operation until 200 l

 

200.000

l

appears on the display.

 

 

 

 

 

 

 

The display blinks and the set value is displayed for

 

H1: COUNT

RATE

confirmation.

 

 

 

Press

 

MENU/ENT

again to write the data. Then the cursor

 

200.000

l

 

 

disappears and the display returns to the condition that the set

 

 

 

 

 

 

value is displayed.

H1: COUNT RATE

Returns to the menu of setting item selection.

Note: The indicting units for count rate are displayed cyclically as shown below.

m3 l ml galbbl pt qt