6F8A0917
Referring to 5.2 "External Connections," connect each cable to the terminal block. Tighten the screws of the terminal block tightly to make them securely connected. A loose connection may cause incorrect measurement. After connecting each cable, try to pull it to check whether it has been connected securely.
Phillips screwdriver
* The appropriate torque for tightening the terminal block screw is 1.2 N m
Terminal block
Figure 5.7 Connection to Terminal Block
After connecting the cables to the terminal block, take up the slack of the cables and tighten the cap nut.
At this time, be careful that if the
Cable connection
Cap nut for tightening
Cable
Packing
Correct
Cable connection
Because the contact surface of the cable and the packing is small, air tightness may not be kept.
Incorrect
Figure 5.8 Cable Tightening
- 26 -